Wheeler incremental inductance rule
id:
wheeler-incremental-inductance-rule-279-16473822
title:
Wheeler incremental inductance rule
text:
The incremental inductance rule, attributed to Harold Alden Wheeler by Gupta and others is a formula used to compute skin effect resistance and internal inductance in parallel transmission lines when the frequency is high enough that the skin effect is fully developed. Wheeler's concept is that the internal inductance of a conductor is the difference between the computed external inductance and the external inductance computed with all the conductive surfaces receded by one half of the skin dept
brand slug:
wiki
category slug:
encyclopedia
description:
Rule of thumb for estimating skin effect resistance of parallel transmission lines