The open-circuit saturation curve of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field. The curve is typically plotted alongside the synchronous impedance curve. At the low field, the permeable iron in the magnetic circuit of the generator is not saturated, therefore the reluctance almost entirely depends on the fixed contribution of the air gap, so the part of the curve that starts at the point of origin is a linear "air-gap li